Fiberglass Wool Insulation for PEB/Metal Roofs for Textile Industry

Now days many textile players prefer Pre Engineered Building (PEB) Systems – a complete package of low rise steel buildings manufactured and delivered to the site by a single supplier. The package comprises of rigid structural steel, cladding system and building accessories. Though the concept is simple, PEBs are extremely diversified in their usage and uniqueness in each design. The PEB concept has gained widespread popularity in the last few years as a result of the speed and simplicity with which such buildings can be erected. In addition, many traditionally designed industrial buildings are also now opting for metal roofing.A critical and necessary ingredient in the PEB System is the thermal and acoustic insulation. This is necessary to minimize the heat gain (or energy loss, for an air conditioned building) as well as to provide acoustic insulation from heavy rain and other outside noises. In a typical PEB structure, the roof accounts for approx. 40 to 50% of total heat gain, while walls account for approx. 15 to 20% of heat gain.

Almost 100% of PEBs world-wide are insulated for the following reasons, which are addressed in further detail below :

  1. Minimize heat gain.
  2. Maximize thermal comfort.
  3. Minimize energy loss, cooling load and operating cost for Air conditioned building.
  4. Provide acoustic insulation.
  5. Prevent unwanted moisture condensation.

Minimize heat gain and maximize thermal comfort

As MNCs have put up new facilities in India, they have insisted that the workplace meets internationally accepted norms. This is because of the increased awareness of harmful effects of thermal stress, the physiological effect of high temperature and humidity, and the harmful effect of noise on human health. As a result, architects and planners are paying more attention to this aspect in the last few years.

As per ISO 9241, a typical work place environment should have a temperature less than 23oC and noise level less than 60 dB(A). Depending on process/product, human activities and the number of occupants, the work place temperature varies. It is impossible to achieve thermal or acoustic comfort inside a pre- engineered metal building (which does not have centralized air conditioned system) without adequate insulation. Minimization of heat gain is also very important from medical point of view as heat stress not only reduces productivity but also aggravates heart problems.

By using fiberglass wool as under-deck insulation, heat transmittance through the roof and wall is reduced substantially. Sufficient temperature drop occurs across the roof and wall system, resulting in lower temperature and a comfortable workplace environment.

Minimize Energy Loss

If the PEB is centrally air conditioned, a project owner can reduce the capital as well as operating cost of chiller, motor and AHU by providing adequate thermal insulation. Thermal insulation having sufficiently high thermal resistance (R value) should be installed on roof and wall. Air conditioning load can be reduced substantially and hence one can save scarce fuel energy/electric energy. This is the reason why it is called the product for sustainable development.

Acoustic Benefit

A noisy workplace reduces working efficiency, concentration, and negatively impacts overall performance. Consider the noise inside a PEB shed without insulation which is bombarded with heavy drops of rain or hail which occurs during Monsoon every year. Mumbai recently recorded highest rain fall of 39 mm/hr for 24 hrs. With that sort of rain the sound level of a 10 m x 5 m metal roof can reach 78 dB(A) which is roughly equivalent to the noise in major traffic on a road at 10 m distance on a continuous basis. To maintain acoustic privacy or keep sound level under the specified level i.e 55 dB(A), fibrous type insulation like Glass-wool is the best choice.

table_twigaControl on Condensation

Condensation should be strictly controlled in PEBs as structural metal in contact with condensed water droplets can corrode. To prevent moisture, proper insulation thickness and thermal resistance of the insulation is of utmost importance so that the surface temperature of the same does not go below the dew point temperature. Please note, using aluminum foil on its own as a vapor-retarder does NOT control condensation.